大模板安裝、拆除工程安全作業交底.doc
進入下載頁
內容摘要:
1、 平模存放時應滿足地區條件要求的自穩角,兩塊大模板應采取板面對板面的存放方法,長期存放模板應將模板換成整體。大模板存放在施工樓層上,必須有可靠的防傾倒措施,不得沿外墻圍邊放置,應垂直于外墻存放。
2、 沒有支撐或自穩角不足的大模板,要存放在專用的堆放架上,或者平堆放,不得靠在其它模板或物件上,嚴禁下腳滑移傾倒。
3、 模板起吊前,應檢查吊裝用繩索、卡具及每塊模板上的吊環是否完整有效,并應先拆除一切臨時支撐,經檢查無誤后方可起吊。模板起吊前,應將吊車的位置調整適當,做到穩起穩落,就位準確;禁止用人力般動模板,嚴禁模板大幅度擺動或碰倒其它模板。
4、 筒模可用拖車整體運輸,也可拆成平模用拖車水平疊放運輸。平模疊放時,墊木必須上下對齊,綁扎牢固。用拖車運輸,車上嚴禁坐人。
5、 在大模板拆裝區域周圍,應設置圍欄,并掛明顯的標志牌,禁止非作業人員入內。組裝平模時,應及時用卡具或花籃螺絲將相鄰模板連接好,防止傾倒。
6、 全現澆結構安裝作模板時,必須將懸挑擔固定,位置調整準確后,方可摘鉤;外模安裝后,要立即穿好銷桿,緊固螺栓。安裝外模板的操作人員必須持好安全帶。
在模板組裝或拆除時,指揮拆除和掛鉤人員,必須
Abstract:
1, flat-mode storage conditions should be required to meet the region from the stable angle, two large formwork panels should be taken to the storage method of the face board, long-term storage of template template should be replaced as a whole. Great template stored in the construction of floors, we must have a reliable anti-dumping measures shall be placed along the outer wall of the sides should be placed perpendicular to the wall.
2, there is no support or lack of large angle from the stable template, to be stored in a dedicated stacking shelves, or flat stacked, not leaning against other templates or objects prohibited the dumping of substandard slip.
3, before lifting the template, check the hoisting rope, fixtures and rings on every block of the template is complete and effective, and should remove all the temporary support, only after lifting by the checking is correct. Before lifting the template, the location of the cable car should be adjusted appropriately, so that from the stable steady drop, place and accurate; prohibit the use of human-like dynamic template, the template is strictly prohibited swing or pushed down by a significant other templates.
4 cylinder model available overall transport trailer, and removable into the flat die stacking with the level of the transport trailer. Stacked flat die, the skid must be aligned up and down, lashing firm. Trailer transport, take people on board is strictly prohibited.
5, dismantling a large area around the template, should be set up fences and hanging obvious signs prohibiting entry to non-operating personnel. Assembly of flat die, they shall be used fixtures or Turnbuckles connect the adjacent template to prevent dumping.
6, the whole place for the template structure installation, you must be hanging knows the weight of fixed position adjustment accurately, before uncoupling; outside the model installed, immediately put on bar sales, tightening bolts. Installed outside the template operator must hold your seat belts.
In the template assembled or dismantled, removed and linked command staff must